Find the right steel studs limiting heights and spans and fire rated assemblies for your shaft walls.
Usg defelction criteria for metal sud framing tile wall.
Recent research has shown tile to fail under some conditions when the floor is more rigid than l 360.
Shear stress of the stud.
Shafts are enclosed early in construction and the walls are finished later along with interior partitions.
Spaced not more than 12 in.
Framing practices and procedures for wood and steel framing.
Axial load on the stud.
Ceiling framing must be capable of supporting the total ceiling dead load including insulation ceramic tile bonding materials and tile backer board with deflection not exceeding l 360.
Installation is quick and easy using components and application procedures familiar to drywall contractors.
These wall assembly files are used for planning and estimation purposes for many ul wall types such as fire rated wall assemblies.
Includes details for resilient channel installation chase walls furred ceilings and walls and door and window openings.
Bending stress of the steel stud.
Cgc shaft wall systems are non load bearing gypsum wall partition assemblies constructed from outside the shaft at each floor.
Floor framing must be covered with min 19 mm 3 4 exterior grade plywood subfloor firmly attached to assure stability.
Also beads trims framing insulation fasteners adhesives joint compounds coatings tapes plaster finishes and textures.
Using l 240 as an example and where the length of a span distance between supports is 3 metres deflection is determined as follows.
Web crippling of stud at supports.
If framing is 16 in.
Our wall framing system are comprised of zincalume zinc and aluminium coating that comes with thickness ranging from 0 5mm and above.
Allowable deflection of the stud.
Our wall frames provide a durable practical and lightweight structure for internal plasterboard walls and for specific external wall systems.
Use 20 gauge steel studs for exterior non loadbearing curtain.
Access our all new collection of sound tested fire rated wall assemblies.
L d deflection limit 240 l 3 m or 3000 mm 3000 d 240 d 12 5 mm.
We use cookies to provide a personalized site experience.
Stud selection selection of a stud gauge and size must take into account a num ber of factors.
Usg provides resources here for our ul wall assemblies for seamless integration into any construction project.
The preferred limit for veneer assemblies is l 360 and should not exceed l 240.
For example while joist manufacturers regularly meet the standard l 360 criteria for code construction with 24 o c.
On center systems these floors often have deflection between the joists exceeding l 360.
Estimate materials and find usg equivalents for your building projects.
9 5 mm greater than the total thickness of the gypsum board being fastened.
Screw lengths must be not less than 3 8 in.