It needs to dry and then stay dryto avoid flooring problems.
Vapor barrier walls concrete.
In hot climates any moisture that condenses on the exterior side of the vapor barrier will be drained to the exterior since the vapor barrier is also a drainage plane.
So there is enough gap for air to flow.
A vapor barrier against the concrete surface is generally recommended before wood framing or flooring materials are installed.
This wall assembly will dry from the vapor barrier inwards and will dry from the vapor barrier outwards.
If you have a framed wall that is adjacent to a concrete foundation wall where the vapor barrier is next to the drywall in front of the studs the fiberglass insulation gets wet and becomes a breeding ground for mold.
Designed to provide superior resistance to gas and moisture transmission perminator evoh is a highly resilient underslab gas vapor barrier designed to restrict naturally occurring gases such as radon methane gasoline solvents oils and hydrocarbons from migrating through the ground and into the concrete slab.
When the mold grows it will spread to everything around it studs drywall etc.
While current practices versus old methods are under some debate the rule of thumb is that a vapor barrier is installed on the warm side of the insulation in a wall.
That is if the studs are going to touch the concrete wall.
Or you can leave a 4 inch gap between the studs and concrete wall and probably get away with it.
Most poly vapor barriers don t meet the permeance rating of 10 or better which.
Very hot and humid climates may benefit from an exterior vapor barrier that keeps outside humidity from penetrating into walls.
The construction of the wall for instance is vital to the use of a vapor barrier.
Visqueen or poly is made from low grade resins and recycled materials that can break down over time.
A concrete vapor barrier is any material that prevents moisture from entering a concrete slab.
Perminator evoh underslab gas vapor barrier.
Vapor barriers are used because while fresh concrete is poured wet it s not supposed to stay that way.
Perminator evoh is available in 20 mil thickness and furnished in 150 45 7 m long rolls.
Concrete vapor barrier 1.
Below grade walls and floor slabs transmit ground moisture through concrete walls or slabs.
Frame wall with cavity insulation and brick or stone veneer.
Most jurisdictions require a 4 mil plastic sheet vapor barrier for basement walls against concrete.
Building codes usually require a vapor barrier 4 mil plastic sheeting on exterior basement walls if the framing is attached to masonry or concrete surfaces or if the wood framing butts up against the outer basement walls.